เครื่องกำเนิดไฟฟ้า FG WILSON รุ่น P9.5-4
Minimum Rating
8.5 kVA / 6.8 kW
Maximum Rating
11.0 kVA / 8.8 kW
Emissions/Fuel Strategy
EUIIIa Emissions Compliant
Full Specifications
Generator Set Specifications
Minimum Rating | 8.5 kVA / 6.8 kW |
Maximum Rating | 11.0 kVA / 8.8 kW |
Emissions/Fuel Strategy | EUIIIa Emissions Compliant |
50 Hz Prime | 8.5 kVA / 6.8 kW |
50 Hz Standby | 9.5 kVA / 7.6 kW |
60 Hz Prime | 10.0 kVA / 8.0 kW |
60 Hz Standby | 11.0 kVA 8.8 kW |
Frequency | 50 / 60 Hz |
Speed | 1500 or 1800 RPM |
Voltage | 220-415 Volts |
50 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. |
60 Hz Prime Rating | These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). |
50 Hz Standby Rating | Standard reference conditions 25�C (77�F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. |
Engine Specifications
Engine Model | Perkins® 403D-11G |
Bore | 77.0 mm (3.0 in) |
Stroke | 81.0 mm (3.2 in) |
Governor Type | Mechanical |
Displacement | 1.1l (69.0 cu. in) |
Compression Ratio | 23:01 |
Benefits & Features
The Story
The 6.8 – 25 kVA range of generator sets is designed to power your every need. With an enhanced choice of power nodes, this range is engineered for optimum performance in diverse applications including construction, residential, retail and telecommunications. The contemporary design of the polymer enclosure option redefines durability in the marketplace and further enhances this range alongside the more traditional metal enclosure. For a life without interruptions, trust FG Wilson.
Industry Leading Perkins Engine
The 400 Series engines offer highly competitive performance, fuel economy and EUIIIa Emissions compliance on selected nodes. These engines have been designed to be reliable and to offer low cost of ownership in the wide variety of markets they serve.
Alternator
Benefiting from the well-established Leroy Somer alternator, known worldwide for providing power generation expertise and solutions offering longlife products with low maintenance
DCP10
The FG Wilson DCP range allows you to monitor and control your generator set with ease, providing important diagnostic information whilst ensuring your unit operates within safe parameters. FG Wilson DCP digital control panels, provide simple, intuitive menu navigation and control of your generator set operations. Key information is displayed via the LCD screen and LED’s using universally recognised symbols, eliminating the need for complex instructions or language settings.
Deep Sea DSE4520
The DSE4520 is a compact Auto Mains (Utility) Failure Control Module that has been developed to provide an outstanding range of features within a compact enclosure. Monitoring engine speed, oil pressure, coolant temperature, frequency, voltage, current, power and fuel level, the modules will give comprehensive engine and alternator protection. This will be indicated on a large back-lit LCD icon display via an array of warning, electrical trip and shutdown alarms.
Single-Source Supplier
Fully prototype tested with certified torsional vibration analysis available
World Wide Product Support
FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network
Standard Reference Conditions
Prime Rating – These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating – These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Optional Equipment
Exhaust
- Industrial, Residential, Critical Silencers
Alternator
- Quadrature Droop Kit (AR6)
- Anti-Condensation Heater and Panel Circuitry (AH1)
Control Panels
- PowerWizard 1.1 Control Panel (PWT1.1)
- PowerWizard 1.1+ Control Panel (PWT1.1+)
- PowerWizard 2.1 Control Panel (PWT2.1)
- Deep Sea DSE7420
Starting/Charging
- Lead Acid battery (Dry)
General
- Upgrade to Standard Set for “CE” Certification
- EEC Declaration of Conformity
- Narrow, Wide or Skid Base
- Sound attenuated, steel or galvanised enclosure
- Dual Wall fuel tanks
Standard Equipment
Engine
- Air Cleaner
- Lube oil drain valve
- Engine filled with lubrication oil
- High Coolant Temperature Shutdown
- Low Oil Pressure Shutdown
Cooling
- Package mounted radiator
- Radiator & Cooling Fan
- Coolant Drain Valve
- Fan, Fan drive and battery charging Alternator drive fully guarded to meet EC Machinery Directive
- Cooling System filled with Coolant mix
Exhaust
- Exhaust flange outlet
- Exhaust stub pipe and gasket
Fuel
- 8 Hr Fuel Tank or Skid base
- Fuel Fittings for Local and Remote Feed
Alternator
- Leroy Somer
- SHUNT Excitation
- IP23 Protection
Control Panel
- DCP-10 / DeepSea DSE 4520
Mounting
- Base, Formed Steel with Skid base or Single wall Fuel Tank
- Certified Base Mounted Lifting Eyes, and Rear Drag Eyelets
- Anti-vibration mounts
- Battery Tray and Cables
รีวิว