เครื่องกำเนิดไฟฟ้า FG WILSON รุ่น P1650-1
Minimum Rating
1500.0 kVA / 1200.0 kW
Maximum Rating
1500.0 kVA / 1200.0 kW
Frequency
60 Hz
Full Specifications
Generator Set Specifications
Minimum Rating | 1500 kVA / 1200 kW |
Maximum Rating | 1650 kVA / 1320 kW |
Emissions/Fuel Strategy | Fuel Optimised |
50 Hz Prime | 1500 kVA / 1200 kW |
50 Hz Standby | 1650 kVA / 1320 kW |
Frequency | 50 Hz |
Speed | 1500 RPM |
Voltage | 220-415 Volts |
Engine Specifications
Engine Model | Perkins® 4012-46TAG2A |
Bore | 160 mm (6.3 in) |
Stroke | 190 mm (7.5 in) |
Governor Type | Electronic |
Displacement | 45.8l (2797.5 cu. in) |
Compression Ratio | 13.0:1 |
Benefits & Features
Our Large Product Range
Our Large Product Range of generator set models is available from 730 – 2500 kVA. These generator sets are proven in the field and trusted to provide reliable power for critical applications including: mini power stations, data centres, large factories, airports, hospitals and large retail stores etc. Available with a 50oC package option, to ensure efficient operation in high ambient temperatures, this range can be customised with bespoke enclosures, cooling systems and specialised control systems through our Custom Power Solution team to suit any need.
Industry Leading Perkins Diesel Engine
The 12 cylinder Perkins 4012 range gives you the versatility you need in today’s power generation market. This engine has proven reliability in prime and standby installations in all of the key sectors, such as manufacturing facilities, hospitals, and data centres. The 4012 engines have exceptional power-to-weight ratios and compact designs, making them simple to transport and install.
World Class Alternator
Supported by the Leroy Somer brand with their 100 years expertise in the alternator business, known worldwide for providing industry leading power generation and solutions, offering longlife products with low maintenance
PowerWizard 1.1+
The FG Wilson PowerWizard range of digital control panels, combine straightforward menu navigation with advanced metering and protection technology. They are used in automatic mains failure applications in conjunction with transfer panels. Our PowerWizard range allows you to monitor and control your generator set with ease, whilst ensuring your unit operates within safe parameters and provides important diagnostic information when needed.
Testing & Validation
Fully prototype tested with certified torsional vibration analysis available
World Wide Product Support
FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India • USA With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.
Standard Reference Conditions
Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Optional Equipment
Exhaust
- Industrial, Residential, Critical Silencers
- Catalytic converters
- Heat Exhangers
- Special spark arrestor silencers/certification
Alternator
- Quadrature Droop Kit (AR6)
- Anti-Condensation Heater and Panel Circuitry (AH1)
- Increased alternator ingress protection
- HV alternators
Control Panels
- PowerWizard 2.1
- easYgen-2500, 3200, 3500
- CompAp
- Deep Sea
- Customer tailored PLC System
- Remote monitoring
- Increased Control Panel Ingress Protection
- Stand alone ATI transfer panel
Starting/Charging
- Lead Acid battery (Dry)
- Dual and air starting systems
General
- Upgrade to Standard Set for “CE” Certification
- Sound attenuated enclosures
- Spring, Seismic anti-vibration mounts
- Customer witness test
- Remote cooling
- 50 degree C radiator and package
- Coolant heater
- 4-Pole circuit breaker
- Motorised circuit breaker
- LV and HV switchgear
Fuel
- Bi-fuel options (TWG and TRG only)
- Fuel transfer systems (730 – 900 kVA)
- Integral metal fuel tank (730 – 900 kVA)
Standard Equipment
Engine
- Air Cleaner
- Engine filled with lubrication oil
- Low Coolant Temperature Shutdown
- Perkins 4000, Series 6, 8, 12 and 16 cylinder engine range
- Electronic governor
- Engine mounted fuel/water separator
- Lube drain valve (910 kVA to 2500 kVA)
Cooling
- Package mounted radiator
- Coolant Drain Valve
- Engine mounted battery charging alternator
- Cooling System filled with Coolant mix
- Charge air cooled (excluding TWGs)
Exhaust
- Industrial silencer
Fuel
- Fuel Cooler
Alternator
- Leroy Somer
- AREP Excitation
- IP23 Protection
Control Panel
- PowerWizard 1.1+
Mounting
- Base, Formed Steel with Single wall Fuel Tank
- Lifting points on base frame
รีวิว