เครื่องกำเนิดไฟฟ้า FG WILSON รุ่น P1100-1
Minimum Rating
1000 kVA / 800 kW
Maximum Rating
1100 kVA / 880 kW
Frequency
50Hz
Full Specifications
Generator Set Specifications
Minimum Rating | 1000 kVA / 800 kW |
Maximum Rating | 1100 kVA / 880 kW |
Emissions/Fuel Strategy | Fuel Optimised |
50 Hz Prime | 1000 kVA / 800 kW |
50 Hz Standby | 1100 kVA / 880 kW |
Frequency | 50 Hz |
Speed | 1500 RPM |
Voltage | 220-415 Volts |
Engine Specifications
Engine Model | Perkins® 4008TAG2A |
Bore | 160 mm (6.3 in) |
Stroke | 190 mm (7.5 in) |
Governor Type | Electronic |
Displacement | 30.6l (1864.9 cu. in) |
Compression Ratio | 13.6:1 |
Benefits & Features
Our Large Product Range
Our Large Product Range of generator set models is available from 730 – 2500 kVA. These generator sets are proven in the field and trusted to provide reliable power for critical applications including: mini power stations, data centres, large factories, airports, hospitals and large retail stores etc. Available with a 50oC package option, to ensure efficient operation in high ambient temperatures, this range can be customised with bespoke enclosures, cooling systems and specialised control systems through our Custom Power Solution team to suit any need.
Industry Leading Perkins Diesel Engine
The 12 cylinder Perkins 4012 range gives you the versatility you need in today’s power generation market. This engine has proven reliability in prime and standby installations in all of the key sectors, such as manufacturing facilities, hospitals, and data centres. The 4012 engines have exceptional power-to-weight ratios and compact designs, making them simple to transport and install.
World Class Alternator
World Class Alternator
Supported by the Leroy Somer brand with their 100 years expertise in the alternator business, known worldwide for providing industry leading power generation and solutions, offering longlife products with low maintenance
PowerWizard 1.1 +
The FG Wilson PowerWizard range of digital control panels, combine straightforward menu navigation with advanced metering and protection technology. They are used in automatic mains failure applications in conjunction with transfer panels. Our PowerWizard range allows you to monitor and control your generator set with ease, whilst ensuring your unit operates within safe parameters and provides important diagnostic information when needed.
Testing & Validation
Fully prototype tested with certified torsional vibration analysis available
World Wide Product Support
FG Wilson manufactures product in the following locations: Northern Ireland • Brazil • China • India With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.
Standard Reference Conditions
Prime Rating These ratings are applicable for supplying continuous electrical power (at variable load) in lieu of commercially purchased power. There is no limitation to the annual hours of operation and this model can supply 10% overload power for 1 hour in 12 hours. Standby Rating These ratings are applicable for supplying continuous electrical power (at variable load) in the event of a utility power failure. No overload is permitted on these ratings. The alternator on this model is peak continuous rated (as defined in ISO 8528-3). Standard Reference Conditions Note: Standard reference conditions 25°C (77°F) Air Inlet Temp, 100m (328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2.
Optional Equipment
Exhaust
- Industrial, Residential, Critical Silencers
- Catalytic converters
- Heat Exhangers
- Special spark arrestor silencers/certification
Alternator
- Quadrature Droop Kit
- Anti-Condensation Heater and Panel Circuitry
- Increased alternator ingress protection
- HV alternators
Control Panels
- PowerWizard 2.1
- easYgen-2500, 3200, 3500
- ComAp
- Deep Sea
- Customer tailored PLC System
- Remote monitoring
- Increased Control Panel Ingress Protection
- Stand alone ATI transfer panel
Starting/Charging
- Lead Acid battery
- Dual and air starting systems
General
- Upgrade to Standard Set for “CE” Certification
- Sound attenuated enclosures
- Spring, Seismic anti-vibration mounts
- Customer witness test
- Remote cooling
- Coolant heater
- 4-Pole circuit breaker
- Motorised circuit breaker
- LV and HV switchgear
Standard Equipment
Engine
- Air Cleaner
- Engine filled with lubrication oil
- Low Coolant Temperature Shutdown
- Perkins 4000 Series 8 cylinder engine
- Electronic governor
- Engine mounted fuel/water separator
- Lube drain valve
Cooling
- Package mounted radiator
- Coolant Drain Valve
- Engine mounted battery charging alternator
- Cooling System filled with Coolant mix
- Charge air cooled
Exhaust
- Industrial silencer
Fuel
- Fuel Cooler
Alternator
- Leroy Somer
- AREP Excitation
- IP23 Protection
Control Panel
- PowerWizard 1.1+
Mounting
- Rigid steel base frame
- Lifting points on base frame